thoroughly decarbonized and the crankcase must be flushed
be
fore conversion.
OPERATION
PR
IOR TO OPERATION _____________________________
1. Ensurethatthepowersourcetobeutilizedconformstothe
powersourcerequirementsspecifiedontheproductnameplate.
SeeELECTRICALWIRING&GROUNDINGformore
information.
2. Ensurethattheleverofthepressureswitchisinthe“OFF”
position.Iftheplugisconnectedtoaoutletwhiletheknobisin
the“ON/AUTO”position,thecompressorwillstartoperating
immediatelyandcancauseseriousinjury.
3. Useascrewdriverorsimilartooltoremovetheplasticshipping
capfromtheoilfillhole.
4. Pour“All-SeasonSelect”orotherapprovedoilintotheoilfillhole
tothelevelindicatedonthedipstickprovided.See
COMPRESSORLUBRICATIONformoreinformation.
5. Installthedipstickintheoilfillhole.
6. Inserttheplugintotheoutlet.Ifthepoweroutletonlyloosely
acceptstheplug,theoutletmustberepaired.Contactaqualified
electricianforrepairservice.Theuseofafaultyoutletmay
causeoverheating,resultinginaserioushazard.
•
WA
RNING
Drain the tank to release air pressure before
removingthedipstick.
•
WA
RNING
Make sure the air vent in the dipstick is free
from debris. If the air vent is blocked, pressure
can build in the crankcase and cause damage
to the compressor and possible personal
injury.
7. Positionthecompressoronafirm,levelsurfaceinawell
ventilatedareaawayfrompotentiallyexplosivevapors,gasesor
otheragents.SeeSELECTINGALOCATIONformore
information.
•
CA
UTION
To avoid damaging the compressor, do not
allow the unit to be tilted more than 10° when
operating.
•
CA
UTION
Never operate in temperatures below 32°F
(0°C)orabove104°F(40°C).
STARTING ________________________________________
•
WA
RNING
Wear appropriate personal eye and ear
protectionduringuse.
1. Inserttheplugintotheoutletandstartthecompressorbyturning
thepressureswitchleverto“ON/AUTO”.
•
CA
UTION
Do not stop or start the compressor by use of
the plug. Always use the lever located on the
pressureswitch.
The operation of the compressor is automatic and is controlled
by the pressure switch. The pressure switch stops the
compressor when the pressure in the air tank reaches the
maximum level and restarts the compressor when the air
pressure drops to the restart level.
The motor includes a thermal protection switch which stops the
compressor if the temperature becomes too high. If the switch is
tripped, the compressor will restart only after the reset button is
pushed. See THERMAL OVERLOAD PROTECTION for more
information.
2. Adjustthepressuretotherequiredlevelbyturningthepressure
regulatorknobclockwisetoincreasethepressureand
counterclockwisetodecreasethepressure.
A pressure gauge is provided to indicate when the required
pressure is reached.
•
WA
RNING
Prior to using air tools or attachments, check
the manufacturer’s maximum pressure rating
for that equipment. The compressor outlet
pressure must be regulated to never exceed
the maximum pressure rating of the tools or
attachments.
STOPPING & STORAGE ____________________________
1. Turnthepressureswitchleverto“OFF”.
2
. Unplugthecordfromthepowersourceandsecurethecord
tightlyaroundthehandle.
3. Slowlyopenthetankdrainvalvetodepressurizethetankandto
emptyallaccumulatedwater.Keepyourfaceandeyesaway
fromthedrainvalve.
•
WA
RNING
If the tank becomes corroded, there is a risk of
breakdown. If the tank is not drained, water will
corrode and weaken the air tank causing a risk
of air tank rupture. Drain the tank daily or after
fourhoursofuse.
4. Store the compressor in a clean, dry location.
A = Maximum Oil Level
B =
Minimum Oil Level
A = “ON/AUTO”
B =
“OFF”
http://air.ingersollrand.com